How Hydrophobic Aerogel Felt Helps Reduce Corrosion Under Insulation

Oct 19, 2026

Corrosion under insulation, commonly known as CUI, is a hidden problem in industrial pipelines, storage tanks and process equipment. Moisture can enter an insulation system through damaged cladding, poorly sealed joints, condensation or maintenance openings. Once trapped, the water may remain in contact with the metal surface and create conditions for corrosion.

Because the insulation covers the pipe or equipment, early corrosion is often difficult to detect. By the time staining, leaks or damaged cladding become visible, the metal surface may already have suffered significant deterioration.

Hydrophobic aerogel felt can help reduce water retention within an insulation system. Its moisture resistance, low thermal conductivity and thin flexible structure make it a useful option for industrial projects where CUI is a major concern.

However, aerogel felt cannot prevent corrosion by itself. Effective CUI control requires the correct combination of insulation, protective coating, cladding, joint sealing and regular inspection.

 

What Is Corrosion Under Insulation?

Corrosion under insulation is the deterioration of a metal surface beneath an insulation layer.

It is commonly found on:

Carbon steel pipelines

Stainless steel process pipes

Storage tanks

Pressure vessels

Heat exchangers

Valves and flanges

Steam and condensate systems

Offshore and marine equipment

CUI may occur when water enters the insulation system and reaches the metal surface. Temperature cycling, dissolved salts, oxygen and chemical contaminants can further increase the corrosion risk.

The insulation may hide the affected area, making CUI difficult to identify through ordinary visual inspection.

 

How Moisture Enters an Insulation System

Even when external cladding is installed, moisture may enter through small openings or damaged areas.

Common entry points include:

Open or poorly sealed cladding joints

Damaged metal jacketing

Pipe supports and penetrations

Valves, flanges and instrument connections

Missing or damaged sealant

Improperly installed flashing

Areas opened during maintenance

Condensation inside cold-insulation systems

Water from rain, washdown or fire-protection systems

Once water enters, some conventional fibrous insulation materials can absorb and retain it. The trapped moisture may spread beyond the original entry point and remain against the pipe surface.

 

What Is Hydrophobic Aerogel Felt?

Hydrophobic aerogel felt is a flexible insulation material made by combining silica aerogel with a reinforcing fiber matrix.

Its internal nanoscale structure restricts heat transfer, while hydrophobic surface treatment helps repel liquid water. The reinforcing layer gives the material sufficient flexibility for installation around pipes, elbows, tanks and other curved surfaces.

Hydrophobic aerogel felt is commonly used for:

High-temperature pipelines

Oil and gas processing equipment

Petrochemical facilities

Power plants

LNG systems

Marine and offshore installations

Storage tanks and vessels

Removable insulation jackets

Different grades are available with varying thicknesses, temperature limits, densities and hydrophobic performance.

 

How Hydrophobic Aerogel Felt Can Reduce CUI Risk

Reduced Water Absorption

Hydrophobic aerogel felt is designed to resist liquid-water penetration. When water reaches the insulation surface, the material is less likely to absorb and retain it than many untreated fibrous insulation products.

Lower water retention can reduce the amount of time moisture remains in contact with the metal surface.

However, hydrophobic performance should be verified through technical data rather than assumed from the product name.

 

Faster Drying of the Insulation System

If a limited amount of moisture enters the system, a hydrophobic material may allow it to drain or evaporate more easily instead of being absorbed throughout the insulation layer.

Faster drying can shorten the wet exposure period that contributes to corrosion.

Drying performance also depends on:

Insulation thickness

Cladding design

Drainage

Operating temperature

Ambient humidity

Ventilation

Location of the water-entry point

 

Less Moisture Migration

Water absorbed by conventional fibrous materials may travel through the insulation and affect a larger area than the original leak point.

Hydrophobic aerogel felt limits liquid-water absorption and can help reduce this type of moisture migration. This may make localized cladding damage less likely to wet a long section of the pipeline.

 

Thinner Insulation System

Aerogel felt has lower thermal conductivity than many conventional insulation materials. It can often achieve the required thermal performance with a thinner insulation layer.

A thinner system may provide several CUI-related benefits:

Less insulation volume in which moisture can accumulate

Smaller external cladding diameter

Fewer complicated transitions around supports

Easier access during inspection

Simpler removal and reinstatement

Reduced drying time after limited moisture exposure

The exact thickness must still be determined through thermal calculations.

 

Stable Performance in Wet Environments

When water enters absorbent insulation, its thermal conductivity may increase and its insulation performance may deteriorate.

Hydrophobic aerogel felt is designed to maintain more stable performance when exposed to incidental moisture. This is especially useful for outdoor pipelines, coastal facilities and equipment subject to weather changes.

It should not be interpreted as permission to leave damaged cladding unrepaired. Long-term water entry can still affect the complete insulation system and the underlying metal.

 

Hydrophobic Does Not Mean Waterproof

This distinction is important.

A hydrophobic material repels liquid water, but the complete insulation system may still contain:

Seams

Cut edges

Fasteners

Overlaps

Penetrations

Drainage openings

Metal cladding joints

Water can travel through these areas and reach the pipe surface without being absorbed by the insulation itself.

Hydrophobic aerogel felt therefore reduces one part of the CUI risk-it does not eliminate every route through which moisture can reach the metal.

A reliable system still requires:

Correctly prepared metal surfaces

Suitable corrosion-resistant coating

Properly installed insulation

Sealed external cladding

Correct drainage

Regular inspection

Timely repair of damaged areas

Aerogel Felt vs Conventional Fibrous Insulation

 

Comparison Factor Hydrophobic Aerogel Felt Conventional Fibrous Insulation
Liquid-water absorption Low for properly treated grades Depends on material and treatment
Moisture retention Generally lower May retain water when damaged or saturated
Required thickness Relatively thin Usually thicker for similar thermal resistance
Drying potential Generally better when system design allows drainage May dry slowly after saturation
Installation around complex shapes Flexible and easy to cut Flexible, but thicker systems may be difficult
CUI prevention Helps reduce risk but cannot eliminate it Requires strong moisture protection
Initial material cost Higher Generally lower
Inspection and removal Thin layers may simplify access Greater insulation volume may increase removal work

Actual performance varies by product grade, operating conditions and installation quality.

 

Importance of Pipe Coating

The insulation material should not be treated as the primary corrosion barrier.

Before installing aerogel felt, the pipe or equipment surface should be inspected and protected with a coating suitable for:

Metal type

Operating temperature

Process environment

Outdoor exposure

Expected service life

Project corrosion specification

The surface should be clean and dry before insulation is applied. Existing rust, damaged coating or contamination should be addressed according to the project procedure.

Hydrophobic insulation and a suitable protective coating perform different functions. Both are important in a complete CUI-control system.

 

Importance of External Cladding

External cladding protects the insulation from rain, mechanical damage, chemical splashes and maintenance activity.

Common cladding materials include:

Aluminum

Stainless steel

Galvanized steel

Weather-resistant membranes

Flexible coated fabrics for removable covers

Cladding joints should be positioned and sealed to direct water away from the insulation.

Particular attention should be given to:

Vertical terminations

Pipe supports

Low points

Nozzles

Instrument connections

Valves and flanges

Changes in pipe diameter

Areas exposed to foot traffic or maintenance work

Even high-quality aerogel felt cannot compensate for continuously leaking or incorrectly installed cladding.

 

Installation Practices That Help Control CUI

Inspect the Metal Surface

Before installation, confirm that the surface is clean, dry and properly coated. Do not cover visible corrosion without completing the required surface treatment.

Keep the Insulation Dry

Store aerogel felt in a dry, covered area before installation. Open only the material required for the current work area.

Fit Sections Closely

Avoid large gaps between insulation sections. Poorly fitted joints may create cold spots, condensation and paths for moisture entry.

Stagger Multi-Layer Joints

When installing more than one layer, stagger both longitudinal and circumferential joints.

This improves thermal continuity and prevents several joints from forming one direct path to the pipe surface.

Avoid Excessive Compression

Fasteners should secure the aerogel felt without crushing it. Excessive compression reduces installed thickness and may create uneven thermal performance.

Seal the Cladding Correctly

Cladding should be installed as soon as practical after the insulation is applied. Sealants, overlaps and flashing details must follow the project specification.

Protect Inspection Openings

Any area opened for inspection or maintenance must be properly resealed. Temporary coverings should not become permanent repairs.

Areas That Require Special Attention

Some locations are more vulnerable to water entry and corrosion than straight pipe sections.

Pipe Supports

Supports can interrupt the insulation and cladding. Poor detailing may allow water to collect around the contact area.

Valves and Flanges

These components are frequently opened for maintenance. Removable covers should be designed for reliable refitting and sealing.

Vertical Pipes

Water may travel downward behind the cladding. Correct overlaps and termination details are particularly important.

Low Points

Water can accumulate at the bottom of horizontal pipes, tanks and vessels. Drainage and inspection planning should consider these areas.

Outdoor Equipment

Rain, snow, wind and temperature cycling increase the demand placed on the cladding and sealant system.

Coastal and Offshore Installations

Salt contamination can increase corrosion severity. Moisture entry, chloride exposure and mechanical damage must all be considered.

Inspection and Maintenance

CUI control continues after the insulation system has been installed.

A maintenance program may include:

Visual inspection of cladding

Checking sealant and overlaps

Looking for water staining

Inspecting damaged or dented jacketing

Checking areas near supports and penetrations

Monitoring unexpected surface-temperature changes

Infrared thermography

Moisture detection

Selected insulation removal

Ultrasonic thickness measurement

Inspection frequency should be based on operating temperature, environment, equipment criticality and previous corrosion history.

Hydrophobic aerogel felt may reduce moisture retention, but inspection remains necessary because water can reach the metal through system defects.

 

Selecting Aerogel Felt for CUI-Sensitive Projects

When requesting a quotation, buyers should ask for more than thickness and price.

Important information includes:

Thermal conductivity at relevant temperatures

Maximum continuous operating temperature

Hydrophobicity or water-repellency data

Water-absorption test results

Thickness and density tolerances

Material composition

Fire-performance classification

Chloride and other leachable-ion information, where required

Recommended installation method

Compatible cladding and fastening system

Technical data sheet and safety data sheet

Quality inspection documentation

For stainless steel equipment, project specifications may place limits on chlorides and other substances that could contribute to stress corrosion. Relevant test information should be confirmed before ordering.

 

Information to Provide to the Supplier

To receive a suitable recommendation, provide:

Pipeline or equipment type

Metal material

Normal operating temperature

Maximum and minimum temperatures

Pipe diameter or equipment dimensions

Indoor or outdoor installation

Coastal, offshore or chemical exposure

Required insulation thickness

Surface-temperature or heat-loss target

Existing protective coating

External cladding material

Required testing standards

Previous CUI history

Project quantity and delivery schedule

Complete operating information allows the supplier to recommend an appropriate aerogel insulation blanket and installation structure.

FAQ

 

Can aerogel felt completely prevent corrosion under insulation?

No. Hydrophobic aerogel felt can reduce water absorption and moisture retention, but CUI also depends on pipe coating, cladding integrity, joint sealing, operating temperature and maintenance.

 

Is hydrophobic aerogel felt waterproof?

It repels liquid water, but the complete system is not automatically waterproof. Water may still enter through joints, penetrations or damaged cladding.

 

Can aerogel felt be used outdoors?

Yes. It is suitable for many outdoor industrial applications when installed with a properly designed weatherproof cladding system.

 

Does aerogel felt require a corrosion-resistant pipe coating?

Generally, yes. The coating protects the metal surface, while the insulation controls heat transfer. The coating should be selected according to the metal, temperature and project specification.

 

Can wet aerogel felt be reused?

The material should be inspected for physical damage, contamination and changes in thickness. Reuse should follow the manufacturer's guidance and the project's inspection requirements.

 

Where should CUI inspections focus?

Priority areas include pipe supports, low points, damaged cladding, valves, flanges, penetrations, vertical terminations and locations with previous corrosion history.

Conclusion

 

Hydrophobic aerogel felt can help reduce corrosion-under-insulation risk by limiting water absorption, reducing moisture migration and allowing a thinner insulation system.

These advantages make it suitable for industrial pipelines, storage tanks, petrochemical equipment, power plants and offshore facilities where moisture exposure and limited installation space are important concerns.

However, aerogel felt is only one part of CUI management. The metal surface must be properly prepared and coated, the insulation must be correctly installed, and the external cladding must prevent long-term water entry.

Combining hydrophobic aerogel felt with effective coating, sealing, drainage and inspection practices provides a stronger and more reliable approach to controlling corrosion under insulation.